Installation Instructions
36
11. Turn both rotary selectors "tw" and
"
tr
" into their respective original
positions.
Burner removal
C
B
DE
A
F
4x
1. Switch the power OFF.
2. Shut off the gas supply.
3. Pull power cables from fan motor
A
, gas valve
B
and electrodes
C
.
4.
Pull venturi extension D from the
fan.
5.
Undo gas supply pipe fitting E.
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)