Technical data

7
5608 487 v1.2
Vitocell 100-V Installation Instructions
- For narrow passageways, remove upper and lower
portion of crating and carry DHW tank to its installation
location by means of crating boards mounted on the tank.
- Position tank carefully and remove wood crating.
- Locate tank(s) on flooring or foundation capable of
supporting the weight of the tank(s) filled with water.
- The tank does not require a special foundation and
can be placed directly on the floor. If, for cleanliness
purposes, the tank is to be kept off the floor, a
foundation for each tank or tanks can be used.
Recommended installation clearances for service access
Rear in. (mm) 18 (460)
Sides May be reduced if rear pipe connections
can be reached with less clearance
in. (mm) 12 (300)
Top in. (mm) 36 (900)
Front in. (mm) 24 (600)
Minimum clearances to combustibles
All sides in. (mm) 0 (0)
Floor combustible
CAUTION
Install the DHW tank in a frost-protected and draft-free
room. Otherwise it must be drained when not in use, in
order to reduce the risk of damages caused by freezing.
IMPORTANT
Provide sufficient clearances towards the wall to allow
the aquastat to be operated (if installed).
Tank Set-up
Set-up and Connections
1. Apply Loctite 55 as per supplied instructions to each
tank nipple. Use Loctite 55 provided in the installation
fittings package.
2. Connect female ends of brass adaptors to the tank
nipples.
CAUTION
Do not overtighten the adaptors as this may damage
the Ceraprotect emamel of the tank.