Technical data
180
Coding – Vitocontrol-S, VD2/CT3/CM2
Coding 2
(continued)
Coding in factory setting Possible change
Systems/mixing valve circuit (continued)
C8:31*
1
With remote control unit and for heating circuit,
operation with room temperature feed-back must
be programmed:
Without limiting room influence
C8: 1
to
C8: 30
Room influence limit adjustable from 1 to 30 K
d5: 0 External heating program changeover via plug aVD:
Heating program changes to constant operation
with reduced room temperature
d5: 1 Heating program changes to constant operation
with normal room temperature
E1: 1
With remote control:
Normal day temperature is adjustable at remote
c
o
n
t
r
o
l
u
n
i
t
f
r
o
m
1
0
t
o
3
0
˚
C
/
5
0
t
o
8
6
˚
F
E1: 0 Normal day temperature adjustable from
3 to 23˚C / 37 to 74˚F
N
o
r
m
a
l
d
a
y
t
e
m
p
e
r
a
t
u
r
e
i
s
a
d
j
u
s
t
a
b
l
e
a
t
r
e
m
o
t
e
control unit from 10 to 30˚C / 50 to 86˚F
E1: 2 from 17 to 37˚C / 63 to 99˚F
E2: 50 With remote control:
No display correction of actual room temperature
E2: 0
to
E2: 49
Display correction – 5 ˚C / – 9˚F
to
display correction – 0.1˚C / – 0.18˚F
E2: 51
to
E2: 99
Display correction + 0.1˚C / +0.18°F
to
display correction + 4.9˚C / 8.8°F
Mixing valve circuit
F1: 0 Slab curing function inactive F1: 1
to
F1: 4
Slab curing function adjustable in accordance with
four optional temperature-time profiles (see
page 183)
Please note:
Observe slab curing supplier’s instructions.
Observe local regulations.
Report to be provided by heating contractor must
contain following details:
Heat-up data with their respective supply
temperatures
Max. supply temperature achieved
Operating condition and outdoor temperature
during handover
Function continues after power failure or after
control unit has been switched OFF.
Heating program r
rr
rw
ww
w will be started, after
screed-drying function has been completed or if
address is manually set to 0.
Systems/mixing valve circuit
F2: 8 Time limit for party mode 8 hours
*1
F2: 0 No time limit for party mode
*1
F2: 1
to
F2: 12
Time limit for party mode adjustable from 1 to
12 hours
*1
*1
Party mode ends automatically with heating program r
rr
rw
ww
w when system changes over to operation with normal room temperature.
5351 340 v1.4