Technical data
Spec Sheet
PYROT Rotation Heating System
PYROT - Ecotronic
6800-2
2007-08-13_E
KÖB Holzfeuerungen GmbH, Flotzbachstr. 33, A-6922 Wolfurt, Tel. +43/5574/6770-0, Fax 65707, E-Mail: office@kob.cc
Subject to technical changes
- One KTY sensor with dipping shell, 1/2 " x 280 mm (B28.1, see Spec Sheet 6960-1)
Extensions available for the PYROT Ecotronic Control System (Article ECO-…) at an extra charge:
PYROT Single-unit System:
Designation Article Text Use
Heat generator, bivalent ECO-KP0 4030 Integration System for Electric Boiler
Heat generator, bivalent ECO-KP1 4030 Integration System for Oil/gas-fired Boiler
Controller for Room Heating System ECO-H 4040 optional
Controller for Annex Building ECO-N 4040 optional
Controller for Pipelining System ECO-F 4040 optional
Controller for Air Heater ECO-L 4040 optional
Controller for Utility Water Heater ECO-B. 4040 optional
Controller for Utility Water Circulation System ECO-BZ 4040 optional
Controller for Solar-powered Utility Water Heater ECO-S1 4050 optional
Controller for Solar-powered Utility Water/Heating ECO-S3 4050 optional
Visualisation System for PYROT, internal ECO-VIR 4090 optional (for customer’s PC workplace)
Output Management System ECO-… 6810 Additional heat generation functions
Remote transmission ECO-… 6820 Visualisation, remote maintenance
The control system components for the fuelling system are included in the articles for the various loader systems.
For external fuelling system, see Spec Sheet 6800-3.
PYROT Double-unit System:
The Mastercontrol control system (see Spec Sheet 6850) is mandatory for the installation of a PYROT double-
unit system.
The PYROT double-unit system is a heat-generating facility, in which the load allocated to the biomass is distributed to
two PYROT boilers. The entire thermal load generated is conducted to a joint accumulator in the form of a hydraulic
switcher.
It is necessary to comply with the following for this type of system:
1. Joint fuelling system: Mastercontrol
The control of the joint fuelling system for the PYROT double-unit system is carried out by the Mastercontrol control
system. The control system components for the fuelling system are included in the articles for the various loader
systems.
2. Additional heat generators: Mastercontrol
Extensions for controlling additional heat generators are only allowed in the Mastercontrol (additional control cabinet)
and not in the individual boiler control system (ECO-300 or ECO-540).
3. PYROT Ecotronic Control System, as an individual boiler control system
Only the extensions listed in Spec Sheet 6850 are possible in the Mastercontrol control system.
The PYROT double-unit system is not designed to control heat consumers. (Such control is carried out by customer-
provided building instrumentation and control equipment.)
Using a Mastercontrol turns the PYROT Ecotronic control system into an individual boiler control system, without any
further extensions being possible.