Technical Data Manual Model Nos.
Product Information Vitocell 300-V EVIB Technical Data Benefits Hygienic, convenient and economical Domestic hot water (DHW) heating with DHW tanks made from stainless steel – vertical version Benefits at a glance: Corrosion-resistant tank of high-grade stainless steel offers a long service life. Fully hygienic due to high quality homogeneous stainless steel surfaces. The high-alloy material is immune to cracking or peeling. The tank stays hygienic and requires only minimum service.
Product Information Vitocell 300-V EVIB Technical Data Cross Section Legend A Inspection and cleaning opening B Stainless steel cylinder C Highly effective all-round thermal insulation 6171 192 - 02 D Indirect coil made from stainless steel 3
Technical Data Vitocell 300-V EVIB Technical Data Technical Data 300-V EVIB-42 Suitable for heating systems with: max. working pressure on heat exchanger side up to 220 psig at 392°F (200°C) max. working pressure on DHW water side of up to 150 psig at 210°F (99°C) For domestic hot water heating applications which utilize modulating and low temperature hot water heating boilers.
Technical Data Vitocell 300-V EVIB Technical Data Technical Data 300-V EVIB-53 Suitable for heating systems with: max. working pressure on heat exchanger side up to 220 psig at 392°F (200°C) max. working pressure on DHW water side of up to 150 psig at 210°F (99°C) For domestic hot water heating applications which utilize modulating and low temperature hot water heating boilers.
Technical Data Vitocell 300-V EVIB Technical Data Technical Data 300-V EVIB-79 For domestic hot water (DHW) heating applications which utilize modulating and low temperature hot water heating boilers. Model Storage capacity Supply flow rate for the recovery rates stated Recovery rates*1 with a DHW temperature rise of the domestic hot water from 50 to 140ºF (10 to 60ºC) and heating water supply temperature of...... at the supply flow rate stated above Suitable for heating systems with: max.
Technical Data Vitocell 300-V EVIB Technical Data Technical Data 300-V EVIB-119 For domestic hot water (DHW) heating applications which utilize modulating and low temperature hot water heating boilers. Model Storage capacity Supply flow rate for the recovery rates stated Suitable for heating systems with: max. working pressure on heat exchanger side up to 220 psig at 392°F (200°C) max.
Technical Data Vitocell 300-V EVIB Technical Data Tank Dimensions 42 USG (160 L) and 53 USG (200 L) Tanks Dimensions Model 300-V EVIB Storage capacity USG (L) a b c d e f g h i in. in. in. in. in. in. in. in. in.
Technical Data Vitocell 300-V EVIB Technical Data Tank Dimensions (continued) 119 USG (450 L) Tank Dimensions Model 300-V, EVIB Storage capacity USG (L) a b c d e f g h i j *1 in. in. in. in. in. in. in. in. in. in.
Technical Data Vitocell 300-V EVIB Technical Data Water Flow Model 300-V EVIB Storage capacity USG (L) Domestic hot water draw rate GPM (L/min) Domestic hot USG water draw water (L) with t= 140°F (60°C)(constant) tank volume % 42 (160) 2.6 (10) 35 (133) 83 53 79 119 (200) (300) (450) 2.6 (10) 4.0 (15) 4.0 (15) 41 63 103 (155) (240) (390) 77.
Vitocell 300-V EVIB Technical Data Product Installation Standard Equipment Vitocell 300-V, EVIB 42 USG (160 L) capacity DHW tank made from stainless steel. Integral welded sensor well for tank temperature sensor/temperature controller (internal diameter 7 mm) Temperature and pressure relief valve Installation fittings Technical literature set Adjustable feet Fitted thermal insulation Color of the epoxy-coated sheet steel casing: Vitopearlwhite.
Product Installation Vitocell 300-V EVIB Technical Data Multiple Tank Installation Technical data The DHW tanks may be combined into batteries consisting of 2 tanks [79 USG (300 L)] tanks or 3 [119 USG (450 L)] tanks. Tank batteries consisting of more than 3 tanks can be installed by creating up to 4 batteries, each consisting of 2 tanks. The heating contractor is responsible to ensure proper piping on both the primary and secondary circuits.
Product Installation Vitocell 300-V EVIB Technical Data Multiple Tank Installation (continued) Domestic hot water draw rate Storage tank content heated to 140°F (60°C), boiler not reheating Model Storage tank capacity Number of storage tanks Battery storage capacity DHW draw rate Domestic hot water draw Water with t=140°F (60ºC) (constant) 79 USG (300 L) USG (L) GPM (L/min) USG (L) % of battery volume 300-V, EVIB 119 USG (450 L) 2 158 (600) 2 238 (900) 3 357 (1350) 7.9 (30) 7.9 (30) 11.
Product Installation Vitocell 300-V EVIB Technical Data System Design Guidelines Domestic hot water connections 14 IMPORTANT This is a simplified conceptual drawing only! Piping and necessary componentry must be field verified. Proper installation and functionality in the field is the responsibility of the heating contractor.
Product Installation Vitocell 300-V EVIB Technical Data System Design Guidelines (continued) Boiler hot water connections (single coil) Note: See pages 4, 5, 6 and 7 for technical information. Legend A Vitocell 300 B Boiler * C Domestic Cold Water (DCW) D Domestic Hot Water (DHW) E Boiler supply F Boiler return 6171 192 - 02 * Refer to your specific boiler installation manual for specific boiler connection details.
Product Installation Vitocell 300-V EVIB Technical Data Additional System Information Heating water supply temperature over 230ºF (110ºC) For these operating conditions, an approved high limit must be installed to limit the domestic hot water temperature to 203°F (95°C) in the tank. Temperature and pressure relief valve A 150 psi temperature and pressure relief valve (T&P relief valve) is supplied with the tank.