Install Instructions
Table Of Contents
- About this Document
- Disclaimers
- Product Information
- Viega Manifolds
- Viega PureFlow Tubing
- Viega PureFlow Fittings
- Viega PureFlow System Design Considerations
- Water Service Installation
- Installing the ManaBloc
- Mounting the ManaBloc
- Installing Manifold Distribution Lines
- Installing the Viega PureFlow PEX Tubing System
- Fastening the Viega PureFlow System
- Installing Viega PureFlow Fittings
- Pressure Testing Viega PureFlow Systems
- System Disinfection
- Installer Checklist
- Limited Warranty
Viega PureFlow Fittings
25 of 88
IM-PF 724596 1021 PureFlow Water System (EN)
Pure
Flow
1/2”
▶ Extend the PureFlow press tool handle and continue ratcheting until
automatic tool release occurs at the proper compression force.
CAUTION!
Do not press twice.
5.6 Making Connections with the PureFlow Press Power Tool
▶ Insert PureFlow Press tting with attached sleeve into tubing and
engage fully.
▶ Ensure full tubing insertion at view holes in attached press sleeve. Full
insertion means tubing must be completely visible in at least two view
holes and partially visible in the one.
▶ Insert the appropriate PureFlow press jaw into the press tool and push
in the holding pin until it locks.