Instruction Manual

Set the large flush volume at the drain valve.
Set the small flush volume at the drain valve.
3.3 Errors, faults and remedy
Error Cause Solution
The WC does not flush. The cistern is not yet completely
full.
Wait until the cistern is sufficiently
full.
There is no water in the cistern.
The corner valve is closed.
Open the corner valve.
The WC flush runs through. The seal at the filling valve is dirty
or damaged.
Check the seal, replace if neces‐
sary.
The seal at the drain valve is dirty
or damaged.
Check the seal, replace if neces‐
sary.
3.4 Care and maintenance
3.4.1 Care tips
Use normal soap or a mild cleaning agent for regular care and preven‐
tion of lime scale on the flush plate. Under no circumstances should
scouring agent or scratching objects be used.
Strong stains can be removed using typical household cleaner. Rinse
the detergent thoroughly with clear water after the prescribed exposure
time. There should be no residue on the components.
-
-
Handling
WC flush plate for Prevista Visign for Style 23
16