INT Instructions for Use WC flush plate for Prevista Visign for Style 23 for all Prevista concealed cisterns Model 8613.
Table of contents Table of contents 1 2 About these instructions for use 3 1.1 Target groups 1.2 Labelling of notes 1.3 About this translated version 3 3 4 Product information 5 2.1 Standards and regulations 5 5 2.2 Intended use 2.2.1 Areas of use 3 2.3 Product description 2.3.1 Overview 2.3.2 Technical data 6 6 6 Handling 7 3.1 Assembly Prepare cistern Mounting the flush plate 7 7 8 3.2 Commissioning 3.2.1 Setting the flush volume 15 15 3.3 Errors, faults and remedy 3.
About these instructions for use 1 About these instructions for use Trade mark rights exist for this document; for further information, go to viega.com/legal. 1.1 Target groups The information in this instruction manual is directed at the following groups of people: n Heating and plumbing experts and trained personnel n Consumers Individuals without the above-mentioned training or qualifications are not permitted to mount, install or, if appropriate, maintain this product.
About these instructions for use 1.3 About this translated version This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g. EN) and/or in Germany (e.g. DIN/DVGW). Some passages in the text may refer to technical codes in Europe/ Germany.
Product information 2 Product information 2.1 Standards and regulations The following standards and regulations apply to Germany / Europe and are provided as a support feature. Regulations from section: Technical data 2.2 Intended use 2.2.1 Areas of use Scope / Notice Regulations applicable in Ger‐ many Flush flow DIN 3265 Noise class DIN 4109 Suitable cisterns The flush plate is intended for the actuation of flushes on Viega con‐ cealed cisterns.
Product information 2.3 Product description 2.3.1 Overview 1 2 4 3 Fig. 1: Scope of delivery 1 2 3 4 2.3.2 installation frame flush plate actuating rods retaining bolt Technical data Flush volume The flush volumes for the flush actuation are: n Small flush volume: approx. 2–4 litres n Large flush volume: approx. 3.5–7.5 litres For the setting of the flush see Ä Chapter 3.2.1 ‘Setting the flush volume’ on page 15.
Handling 3 Handling 3.1 Assembly 3.1.1 Prepare cistern Requirements: n The cistern is fitted into the pre-wall. n The pre-wall is tiled. ▶ Cut into the sticky tape of the shaft cover. ▶ Remove the shaft cover. ▶ Cut into the corners of the revision shaft. 4x WC flush plate for Prevista Visign for Style 23 ▶ Fold the sides of the revision shaft outwards up to the tile level and snap them off.
Handling 3.1.2 Mounting the flush plate ▶ Turn the cover plate lock 90° in anti-clockwise direction. ▶ Remove the cover plate. ▶ Close the corner valve. The maximum torque is 4 Nm.
Handling ▶ Loosen the flexible hose on the filling valve. INFO! For setting the flush volume, see Ä Chapter 3.2.1 ‘Setting the flush volume’ on page 15. ▶ Open the corner valve for a few seconds to flush the pipe. ▶ Close the corner valve. The maximum torque is 4 Nm.
Handling ▶ Connect the flexible hose to the filling valve. ▶ Re-open the corner valve. INFO! Check the corner valve and the filling valve for leak tightness. ▶ Insert the cover plate into the cistern. ▶ Turn the cover plate lock by 90° in a clockwise direction.
Handling ▶ Put on the installation frame. ▶ Insert the retaining bolts. ▶ Turn the retaining bolts by 90° in a clockwise direction. ▶ Align the installation frame. ▶ To fix the retaining pins, turn the safety rings in a clockwise direc‐ tion.
Handling NN If you are not sure which cistern is installed, identify it by means of the following dimensions. n 3H concealed cistern ) n concealed cistern 3L NN - n Concealed cistern 3F NN ' INFO! For installation from the front into the concealed cis‐ 9 terns 3H, 3L, 3F. ▶ Determine the distance for the actuating rods.
Handling INFO! Cistern 3H and 3L. ▶ If necessary, cut the actuating rods to length. n 0: 75–50 mm n 1: 50–25 mm n 2: 25–10 mm INFO! Cistern 3F. ▶ If necessary, cut the actuating rods to length. n n n n 1: 75–55 mm 2: 55–35 mm 3: 35–15 mm 4: 15–10 mm INFO! For installation from above into concealed cistern 3L. ▶ Determine the distance for the actuating rods. 9 ▶ If necessary, cut the actuating rods to length.
Handling ▶ Insert the actuating rods as far as they will go. ▶ Align the actuating rods. ▶ Rotate the actuating rods 90° in clockwise direction. 90° 90° ▶ Mount the flush plate. ▷ The flush plate is mounted.
Handling 3.2 Commissioning 3.2.1 Setting the flush volume ▶ Fold the tabs forward. ▶ Lift the drain valve. ▶ Remove the drain valve through the revision opening.
Handling ▶ Set the large flush volume at the drain valve. ▶ Set the small flush volume at the drain valve. - - 3.3 Errors, faults and remedy Error Cause Solution The WC does not flush. The cistern is not yet completely full. Wait until the cistern is sufficiently full. There is no water in the cistern. The corner valve is closed. Open the corner valve. The seal at the filling valve is dirty or damaged. Check the seal, replace if neces‐ sary.
Handling 3.5 Disposal Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.
Viega GmbH & Co. KG service-technik@viega.de viega.