Install Instructions

Table Of Contents
Product Information
21 of 56
IM-PP 599834 0320 ProPress Stainless
As long as the tubing is properly prepped and marked
and the 󶈵tting is installed according to Viega’s
ProPress Stainless Product Instructions, if there is any
de󶈶ection present after the installation of the 󶈵tting,
the connection is still acceptable and meets Viega’s
manufacturing speci󶈵cations for proper installation and
warranty.
De󶈶ection of a press connection has no e󶈴ect on the
integrity of the system, and it can be pressure tested
in accordance with the ProPress Stainless Product
Instructions.
Re-Press
Press the 󶈵tting, once on each side (that is, re-press the 󶈵tting a
second time on the opposite side). Pressing the same connection
from the opposite side will usually straighten misalignment between
the tube and 󶈵tting.
When pressing overhead piping, it may be inconvenient to alternate
sides for each press.
The natural weight of the piping plus pressing on opposite sides at a
45 degree angle should adequately eliminate de󶈶ection.
This technique can also be used for any horizontal piping and also
when working above the piping.
2.6 ProPress Stainless Flow Data
Nominal Tube Size
(inches)
Weight
Tube (lb./ft.) Water (lb./ft.) Total (lb./ft.)
½ 0.41 0.06 0.47
¾ 0.59 0.12 0.71
1 0.77 0.20 0.97
0.95 0.31 1.26
1.13 0.43 1.56
2 1.50 0.76 2.26
2.18 1.61 3.79
3 2.60 2.29 4.89
4 3.46 4.06 7.52
Table 3: Dimensional data