User Guide
Table Of Contents
- Introduction
- Codes, Standards, and Certifications
- PureFlow Press Fittings
- PureFlow Crimp Fittings
- PureFlow Tools
- Product Instructions
- Tubing Overview
- Design Considerations
- ManaBloc Systems
- Installing PureFlow Systems
- Storage Recommendations
- Handling Viega PureFlow PEX Tubing
- Removing PureFlow Connections
- Repairs
- Freezing
- Water Heaters
- Heaters, Flues, Vents, and Recessed Lights
- Fastening the PureFlow System
- Supporting PureFlow PEX Tubing
- Installation Considerations
- Noise and Water Hammer
- Shower Valves
- Electrical Grounding
- Expanding Foams
- Fire Stop Compounds
- Tubing Expansion
- Calculating Expansion Loops and Offsets
- Domestic Hot Water Circulating Systems
- Installing Viega PureFlow Fittings
- PureFlow PEX Tubing Installed in Slab
- Installing PEX Under a Slab
- Installing PEX Below Grade as Service Line
- Pressure Testing PureFlow Systems
- System Disinfection
- Limited Warranty
ManaBloc Systems
30
PG-PF 724998 0320 PureFlow System
5. Standing in front of the wall, using a
framing square or straight edge, mark the
center line position of the top and bottom
ports onto both studs.
Mark the centers of the top
and bottom ManaBloc ports
(A, B)
6. Detach the ManaBloc from its mounting
straps (or 1x4s) and remove it from the
installation area to prevent wood chips
or other debris from falling into the unit.
7. Transfer the port location marks made
in Step 5 to the insides of the stud
cavity using a square and pencil.
8. Measure 1⅝" from the mounting
surface. Draw a vertical line on the
studs that passes through each of the
horizontal port center lines marked in
Step 7. Be sure to mark the inside of
both studs.
1⅝"
9. Push a small nail through the printed
center line at one end of the Drill
Guide (A). Push the nail into the cross
formed where the top port mark
intersects with the 1⅝" mark. Tap
the nail into the stud to hold the Drill
Guide in place.
10. Push a small nail through the printed
center line on the lower end of the
Drill Guide with the center line of the
port (B). Tap the nail into the stud to
hold the Drill Guide in place.
11. Using an awl, nail, or other pointed
tool (C), mark the stud by tapping
through the Drill Guide at each printed
center line between the two nails.
12. Carefully remove the Drill Guide and repeat
the marking procedure on the adjacent stud.
13. Drill ¾" holes through both studs at
each marked location. Be sure to
hold the drill level, perpendicular to
the stud to prevent drilling holes at an
angle. Remove any splinters or burrs
made during drilling.
14. Mark and drill any holes for main
water supply and hot water supply/
return lines at this time. A 1¼" bit will
provide adequate clearance for ¾" or
1" tubing. The tubing shall enter and/
or exit the ManaBloc in a straight line
so as not to induce bending stress
on the ManaBloc. Necessary elbows,
couplings, and tees are allowed in the
main water supply lines.
Drill ¾" holes for
distribution lines,
1¼" holes for
supply lines.
15. Reattach the ManaBloc to the
mounting straps.
When the ManaBloc is installed
prior to wall nishing operations,
the unit MUST be protected from
paint, texture compounds, and drywall dust.