User Guide
Table Of Contents
- Introduction
- Codes, Standards, and Certifications
- PureFlow Press Fittings
- PureFlow Crimp Fittings
- PureFlow Tools
- Product Instructions
- Tubing Overview
- Design Considerations
- ManaBloc Systems
- Installing PureFlow Systems
- Storage Recommendations
- Handling Viega PureFlow PEX Tubing
- Removing PureFlow Connections
- Repairs
- Freezing
- Water Heaters
- Heaters, Flues, Vents, and Recessed Lights
- Fastening the PureFlow System
- Supporting PureFlow PEX Tubing
- Installation Considerations
- Noise and Water Hammer
- Shower Valves
- Electrical Grounding
- Expanding Foams
- Fire Stop Compounds
- Tubing Expansion
- Calculating Expansion Loops and Offsets
- Domestic Hot Water Circulating Systems
- Installing Viega PureFlow Fittings
- PureFlow PEX Tubing Installed in Slab
- Installing PEX Under a Slab
- Installing PEX Below Grade as Service Line
- Pressure Testing PureFlow Systems
- System Disinfection
- Limited Warranty
20
PG-PF 724998 0320 PureFlow System
PureFlow Press Zero Lead Bronze Fittings
Size Coupling Elbow
Tee
Run
Tee
Branch
⅜" 2.9 9.2 2.9 9.4
½" 2.0 9.4 2.2 10.4
¾" 1.0 8.0 1.0 9.0
1" 1.0 10.0 2.0 10.0
1¼" 2.0 11.0 2.0 11.0
1½" 2.0 13.0 2.0 12.0
2" 1.0 19.0 2.0 18.0
PureFlow Press Polymer Fittings
Size Coupling Elbow
Tee
Run
Tee
Branch
⅜" 4.5 14.3 6.5 14.7
½" 2.6 12.6 3.9 14.0
¾" 2.5 18.9 3.6 19.1
1" 3.1 17.7 3.8 18.4
1¼" 4.0 18.6 6.4 18.7
1½" 5.2 29.4 7.9 28.3
2" 8.9 36.4 10.2 37.5
Viega PureFlow Press Friction Loss
Equivalent feet of SDR9 PEX tubing
Viega PureFlow Crimp Friction Loss
Equivalent feet of SDR9 PEX tubing
Design Considerations
PureFlow Crimp Eco Brass Fittings
Size Coupling Elbow
Tee
Run
Tee
Branch
⅜" 2.9 9.2 2.9 9.4
½" 2.0 9.4 2.2 10.4
¾" 0.6 9.4 1.9 8.9
1" 1.3 10.0 2.3 11.0
PureFlow Crimp PolyAlloy Fittings
Size Coupling Elbow
Tee
Run
Tee
Branch
⅜" 10.9
22.3 N/A N/A
½" 7.1
16.5 7.2 17.9
¾" 4.8
17.4 6.6 17.7
1" 4.5
18.0 6.0 17.0
Viega PureFlow systems should be
designed following standard plumbing
engineering practice. Follow local codes
to determine minimum tubing size and
required xture pressures.
Pressure drop through ttings can
be estimated from the charts on the
following pages. Values are expressed
in equivalent length of tubing, so add
the values for the relevant ttings to the
length of tubing in the run, and then
determine the total pressure drop from
the charts.
General System Sizing and Calculations
To determine the pressure drop through
runs of Viega PureFlow PEX and
FostaPEX tubing, refer to the “Viega
PureFlow Press Friction Loss” tables
below. For a known ow rate, tubing size,
and tubing length, the pressure drop
through the run can be easily determined.