Install Instructions

Table Of Contents
Installing Manifold Distribution Lines
55 of 88
IM-PF 724596 1021 PureFlow Water System (EN)
10.3.2 Port Connections for PureFlow Crimp Connections
The water supply to the ManaBloc and the port valves shall be turned o󶈴
before attempting installation of crimp adapters.
CAUTION!
Use only sealing elements supplied with the adapters.
1. Ensure sealing element (A) is in place.
2. Slide the supplied swivel nut (D) and a crimp ring (C) onto the tubing
and insert the barbed end of the 󶈵tting (B) fully into the end of the
tubing as shown.
3. Ensuring sealing element (A) is in place and clean of any dirt or debris,
wet sealing element with tap water.
4. Insert 󶈵tting (B) into desired port until the 󶈵tting 󶈶ange sets 󶈶ush with
the end of the port.
5. Slide the crimp ring (C) to within ⅛" to ¼" from the end of tube. Crimp
the ring with an appropriately sized full-circle crimp tool. DO NOT
CRIMP TWICE (see "5.7 Making Connections with the PureFlow Crimp
Hand Tool" on page 27).
6. Slide the swivel nut (D) over the crimped ring (C) and thread the
nut onto the ManaBloc port. HAND-TIGHTEN ONLY. Open the port
valve(s) before turning on the main water supply.
BCD
A
B
C
" - ¼"
⅛" to ¼"
D
C