Install Instructions
Table Of Contents
- About this Document
- Disclaimers
- Product Information
- Viega Manifolds
- Viega PureFlow Tubing
- Viega PureFlow Fittings
- Viega PureFlow System Design Considerations
- Water Service Installation
- Installing the ManaBloc
- Mounting the ManaBloc
- Installing Manifold Distribution Lines
- Installing the Viega PureFlow PEX Tubing System
- Fastening the Viega PureFlow System
- Installing Viega PureFlow Fittings
- Pressure Testing Viega PureFlow Systems
- System Disinfection
- Installer Checklist
- Limited Warranty
Installing Manifold Distribution Lines
55 of 88
IM-PF 724596 1021 PureFlow Water System (EN)
10.3.2 Port Connections for PureFlow Crimp Connections
The water supply to the ManaBloc and the port valves shall be turned o
before attempting installation of crimp adapters.
CAUTION!
Use only sealing elements supplied with the adapters.
1. Ensure sealing element (A) is in place.
2. Slide the supplied swivel nut (D) and a crimp ring (C) onto the tubing
and insert the barbed end of the tting (B) fully into the end of the
tubing as shown.
3. Ensuring sealing element (A) is in place and clean of any dirt or debris,
wet sealing element with tap water.
4. Insert tting (B) into desired port until the tting ange sets ush with
the end of the port.
5. Slide the crimp ring (C) to within ⅛" to ¼" from the end of tube. Crimp
the ring with an appropriately sized full-circle crimp tool. DO NOT
CRIMP TWICE (see "5.7 Making Connections with the PureFlow Crimp
Hand Tool" on page 27).
6. Slide the swivel nut (D) over the crimped ring (C) and thread the
nut onto the ManaBloc port. HAND-TIGHTEN ONLY. Open the port
valve(s) before turning on the main water supply.
AB CD
BCD
A
B
C
⅛" - ¼"
⅛" to ¼"
D
C