Mounting the ManaBloc
50 of 88
IM-PF 724596 1021 PureFlow Water System (EN)
9.5 Mounting PureFlow Press and PureFlow Crimp Polymer Manifold
Viega recommends using a minimum of two mounting brackets on
manifolds with three ports and larger.
1. Measure the distance (A) between the rst and last set of manifold
ports (as shown). Using a straight edge, mark dimension (A) on
mounting surface. Ensure the mounting surface is level and suitable to
support the weight of the manifold lled with water.
2. Align the 1¼" lock clips* (B) with the marks transferred on the
mounting surface from Step 1 and attach them using a 1" or longer
screw appropriate for the mounting surface.
* Lock clips sold separately (part number 58075).
3. With the lock clips in the open position, insert the manifold body into
the clips, centering them between the end ports.
4. Push evenly on both ends of the manifold until lock clips snap
manifold body rmly into place.
Note: Lock the clips into their second locking position to adequately
secure the manifold.