Install Instructions

Table Of Contents
Viega PureFlow Fittings
23 of 88
IM-PF 724596 1021 PureFlow Water System (EN)
5.4 Preparing the Tubing
Square o󶈴 tubing to proper length. Uneven, jagged, or irregular cuts
will produce unsatisfactory connections.
Insert PureFlow Press 󶈵tting with attached sleeve into tubing and
engage fully.
Ensure full tubing insertion at view holes in attached press sleeve. Full
insertion means tubing must be completely visible in at least two view
holes and partially visible in the one.
5.5 Making Connections with the PureFlow Hand Tool