Installing Manifold Distribution Lines
54 of 88
IM-PF 724596 1021 PureFlow Water System (EN)
4. Remove tool locater ring (B) and slide swivel nut (C) over tubing as
shown.
5. Ensure sealing element (A) is in place and clean of any dirt or debris.
Wet sealing element with tap water.
6. Insert the tting into the desired port until the tting ange sets ush
with the end of the port.
7. Thread the swivel nut (C) onto the ManaBloc port. Hand-tighten only.
Open the port valve(s) before turning on the main water supply.
B
C
A
C
UNDER NO CIRCUMSTANCES shall any form of thread sealant
(Teon
®
paste, pipe dope, etc.) be used on distribution line
connections. The carriers present in these compounds can
crack the plastic port connections, resulting in leaks and water
damage.
Hand-tighten only. Damage may result if over-tightened.