Viega PureFlow Fittings
26 of 88
IM-PF 724596 1021 PureFlow Water System (EN)
▶ When press connection is complete, open and remove the jaw.
WARNING!
The tool locater ring must be present to ensure a proper
PureFlow Press connection.
CAUTION!
Do not press twice.
▶ Start the pressing process; hold the trigger until the jaw has
automatically released.
▶ Open jaw and position perpendicular over press sleeve, resting it
against the tool locater ring.
The tool locater ring must be in the factory-installed position
while making a press to ensure a consistent leak-proof
connection. It may be necessary to rotate the tool locater
ring to avoid interference between the ring and tool.