PEX Crimp Supply Adapter
Zero Lead ManaBloc
®
Supply Connection
*Zero Lead identies Viega
®
products meeting the lead free requirements of NSF 61-G through testing under
NSF/ANSI 372 (0.25% or less maximum weighted average lead content).
The water supply to the ManaBloc shall be turned off before
attempting installation of crimp supply adapters.
Use only supplied sealing element
Not for use with FostaPEX
1. Slide the supplied swivel nut (D) and a crimp ring (C)
onto the tubing (threads of the nut toward the end of
the tubing).
2. Insert the barbed end of the fitting (B) fully into the end
of the tubing as shown.
3. Slide the crimp ring (C) to within " to ¼" from the
end
of tube. Crimp the ring with an appropriately sized
full-circle crimp tool. DO NOT CRIMP TWICE. Refer
to the current Viega PEX Water Systems Installation
Manual for additional crimping information.
4. Ensuring sealing element (A) is in place and clean of
any dirt or debris, wet sealing element with tap water.
Insert fitting (B) into desired supply port until the fitting
flange sets flush with the port.
5. Slide the swivel nut (D) over the crimped ring (C) and
thread the nut onto the ManaBloc supply port. Hand
tighten only. DO NOT OVER TIGHTEN.
A
B
C
D
C
⅛"
to
¼"
D
C
B
B
1
3
5
2
4

Summary of content (2 pages)