Brochure

Viega LLC 1-800-976-9819 www.viega.us
9
Viega MegaPress Systems
Minimum distance between two Viega MegaPress
press connections ½" to 2"
Pipe
Diameter
Minimum Distance
(in)
Minimum
Distance
(mm)
½"
3
16
5
¾"
3
16
5
1"
3
16
5
1¼" 10
1½" 10
2" 10
Pipe Size
Insertion Depth (in)
½"
1
1
16
¾" 1
3
16
1" 1
1¼" 1
1½" 1
2" 2
minimum
distance
Technical Information
Table 1
Table 2
See Table 2