Install Instructions
IM-PR 566442 1114 (Design Manual)
180
Figure C-1n
Section through heat transfer plate installation with linoleum or vinyl finish floor
NOTE:
Stop Heat Transfer Plate
installation 12" to 16"
before bend.
¾" Plywood
Subfloor:
The thickness
of the plywood
subfloor should
always be installed
in accordance with
the local building
code.
Floor Joist:
Be sure to check with local building codes to ensure
no structural damage will occur due to drilling joists.
Tubing Spacing
(per design)
Climate Trak:
5"W x 19"L have a 1" gap
between Climate Traks, install
1½" off the joist
R-19 Insulation:
Use a Foil Face or Radiant
Barrier to keep a 1" to 2" air
gap between the insulation
and the Traks.
Refer to
local code for insulation
requirements.
Linoleum or Vinyl Floor