Install Instructions
IM-PR 566442 1114 (Design Manual)
142
Figure A-2e
Section through Climate Panel installation above subfloor with linoleum or vinyl finish floor
Figure A-2f
Section through Climate Panel installation on existing slab with plywood
¼" to ⅛" Finish Plywood or Concrete
Fiberboard: Glue and screw plywood or
concrete fiberboard to Climate Panels.
Tubing Spacing
(per design)
Climate Panel:
Screw or staple Climate
Panels to the subfloor
with 10 fasteners per
panel.
¾" Plywood Subfloor:
The thickness of the plywood
subfloor should always be
installed in accordance with the
local building code.
Floor Joist
R-19 Insulation:
Refer to local code for
insulation requirements.
Linoleum or Vinyl Floor
¾" Plywood:
Stagger and fasten plywood to
slab.
Tubing Spacing
(per design)
Climate Panel:
Screw or staple Climate Panels to the
subfloor with 10 fasteners per panel.
Polyethylene Film:
Cover level slab with 6 mil. (min.)
polyethylene film, overlap 4" to 6"
Compact Subgrade
Concrete Slab:
Slab must be level prior to Cli-
mate Panel installation.