Install Instructions
141
IM-PR 566442 1114 (Design Manual)
Figure A-2c
Section through Climate Panel installation above subfloor with carpet
Figure A-2d
Section through Climate Panel installation above subfloor with carpet and plywood cover sheet
Carpet Pad:
(suitable for radiant oor heating) For
minimum height buildup, install carpet and
pad directly over Climate Panels.
Tubing Spacing
(per design)
Climate Panel:
Screw or staple Climate
Panels to the subfloor
with 10 fasteners per
panel.
¾" Plywood Subfloor:
The thickness of the plywood
subfloor should always be
installed in accordance with the
local building code.
Floor Joist
R-19 Insulation:
Refer to local code for
insulation requirements.
Carpet
Floor Joist
Carpet
Carpet Pad:
(suitable for radiant oor heating)
7" Spacing (per design)
Climate Panel:
Screw or staple Climate
Panels to the subfloor
with 10 fasteners per
panel.
¾" Plywood Subfloor:
The thickness of the plywood
subfloor should always be
installed in accordance with the
local building code.
R-19 Insulation:
Refer to local code for
insulation requirements.
If height allows, a ¼" to ⅜" finish plywood
cover sheet can be installed over the
Climate Panel system.