Install Instructions
IM-PR 566442 1114 (Design Manual)
140
Figure A-2a
Section through Climate Panel installation above subfloor with hardwood finish floor
Figure A-2b
Section through Climate Panel installation above subfloor with tiles
A.2 Typical cross sections
Hardwood Flooring
Tubing Spacing
(per design)
Climate Panel:
Screw or staple Climate Panels to the
subfloor with 10 fasteners per panel.
Climate Panel should run perpendicular
to the direction of the hardwood floor.
¾" Plywood Subfloor:
The thickness of the plywood
subfloor should always be
installed in accordance with the
local building code.
Floor Joist
R-19 Insulation:
Refer to local code for
insulation requirements.
¼" - ⅜" Concrete Fiberboard:
Glue and screw concrete fiberboard
to Climate Panels. (Refer to crack
isolation membrane manufacture for
additional requirements.)
Tubing Spacing
(per design)
Climate Panel:
Screw or staple Climate
Panels to the subfloor
with 10 fasteners per
panel. Climate Panel
should run perpendicular
to the direction of the
hardwood floor.
¾" Plywood Subfloor:
The thickness of the plywood
subfloor should always be
installed in accordance with the
local building code.
Floor Joist
R-19 Insulation:
Refer to local code for
insulation requirements.
Tiles
Crack Isolation Membrane (optional)