Install Instructions
137
IM-PR 566442 1114 (Design Manual)
Pressure Drop Table
Expressed as PSI/ft. Pressure Drop
SIZE
GPM ½" ⅝" ¾" 1"
1 .016 .007 .003 .001
1.5 .034 .014 .006 .002
2.2 .069 .034 .013 .004
2.5 .087 .043 .016 .005
3 .122 .050 .023 .007
3.5 .162 .080 .030 .009
4 .208* .100 .039 .011
5 .314 .154 .059 .017
6 .440 .181 .082 .024
7 .586 .287 .109 .032
8 .368 .140 .041
9 .457 .174* .051
10 .556 .211 .062
11 .252 .074
12 .296 .087
13 .343 .101
14 .116
15 .132*
16 .148
17 .166
18 .184
19 .204
20 .224
21 .245
22 .267
Quality Assurance
When the product is marked with the ASTM
F876 designation, it afrms that the product was
manufactured, inspected, sampled and tested in
accordance with these specications and has been
found to meet the specied requirements.
Certifications
- Tested for health effects to ANSI/NSF standard
61 and performance to ANSI/NSF standard 14.
PEX 5006 - Tested and listed to the NSF-pw (CL5) Chlorine
resistance rating for an end use condition of 100% @ 140°F
per ASTM F876, which is the highest Chlorine resistance
rating available through ASTM. When the product is marked
with the PEX 5006 NSF-pw (CL5) designation, it afrms the
product is approved for use in continuous domestic hot water
circulation systems with up to 140°F water temperatures.
- IAPMO Certified
- ICC ES-PMG™ 1038/1015
plumbing and heating systems
- NSF certified to CSA B137.5
(Canadian Standards Association)
- Certified to UL 263 & CAN/ULC S101
(US & Canadian re resistance ratings)
- Certified to ASTM E84 and CAN/ULC S102.2
FS/SD (25/50) (U.S. & Canadian plenum rating)
HUD (Housing and Urban Development) - MR 1276
SDR-9 PEX Tubing
ASTM F876/F877/CTS-OD SDR-9
Part Tubing Wall Nom. Weight Volume(Gal.)
No Size O.D. Thickness I.D. Per Ft Per 100 Ft
35020 ½" 0.625±.004 0.070+.010 0.475 .0600 0.92
35030 ⅝" 0.750±.004 0.083+.010 0.574 .0900 1.34
35040 ¾" 0.875±.004 0.097+.010 0.671 .1200 1.82
35060 1" 1.125±.005 0.125+.013 0.863 .2000 3.04
NOTE: Dimensions are in English units. Tolerances shown
are ASTM requirements. Viega FostaPEX is manufactured
within these specications. (These dimensions do not reect
the outer aluminum and PE layers.)
Minimum Bend Radius
CORRECT:
8 x O.D.
INCORRECT:
PIPE FLATTENS
AT THE BEND
Thermal Conductivity
SIZE Btu/h/ft/°F W(m.°C)
½" .484 .838
⅝" .516 .892
¾" .547 .946
1" .711 1.230
Minimum Burst Pressure (PSI)
Per ASTM F876/F877
SIZE 73°F (23°C) 180°F (82°C)
½" 480 215
⅝" 475 200
¾" 475 210
1" 475 210
EXAMPLE: To calculate the pressure drop of
a ½" line, 40 ft. long, with a 3 gpm ow rate,
calculate .122 psi x 40 ft. = 4.9 psi pressure
drop. Most plumbing codes require 8 psi
residual pressure at the xture. Refer to your
local code requirements.
*Indicates 8 fps maximum velocity required
by some plumbing codes.
NOTE: Maximum ow for each size based on
12 FPS velocity.
PSI x 2.307 = head loss.
Note: FostaPEX tubing may be bent to a minimum of
3.5 x O.D. with use of a Viega pipe bender.