Install Instructions
Viega IM-MTL 0612
724607
26
9. Open XL Ring and place at right
angles on the fitting. XL Ring must be
engaged on the fitting bead. Check
insertion depth.
10. With V2 ACTUATOR inserted into
the tool, open the V2 ACTUATOR as
shown and connect V2 ACTUATOR
to the XL Ring.
11. Place V2 ACTUATOR onto XL
Ring and start pressing process.
Hold the trigger until the Actuator
has engaged the XL Ring. Keep
extremities and foreign objects away
from XLRing and V2 ACTUATOR
during pressing operation to prevent
injury or incomplete press.
12. Release V2 ACTUATOR from XL
Ring and then remove the XL Ring
from the fitting on completion of
press. Remove tag from fitting,
indicating press has been performed.