Brochure
Water
Air
9
Viega 1-800-976-9819 www.viega.com
Security under pressure
When pressure testing a system after all fittings have been
installed, Viega recommends a step test to ensure that all
connections have been pressed. Testing the system at full
pressure initially may result in a false positive reading. By
testing at a lower pressure first, Viega’s patented Smart
Connect feature will identify which fittings have not been
pressed. Viega recommends the Smart Connect feature
be tested at 15 to 85 psi when testing with water or .5 to
85 psi when testing with air. After ensuring that all connections
have been correctly pressed, installers may increase the test
pressure to full system test requirements.
Security with
Smart Connect
High-quality
sealing element
High-quality fitting
body material
Cylindrical
pipe guide