Applications
The Viega Zone Control is a wiring and switching
center for individual and / or multi- room control.
The Zone Control simplies wiring between
Thermostats and Powerheads. LED lights on
housing indicate individual zone heat demand.
Available as a 4 or 6 zone, both with priority. Zone
Control includes optional circulator activation
function and built in transformer.
Features
• LED indicator lights
• 4 or 6 Zone Control options
• Simplied wiring
• Built in transformer
Specifications
Control Input:
Control Output:
Transformer:
Fuse:
Pump End
Switch Rating:
Main / Priority End
Switch Rating:
Powerheads:
Codes and Standards:
Operation
The green LED indicates that the control is
powered on. When any thermostat calls for heat
that corresponding yellow LED light is illuminated.
A call for heat energizes the corresponding
powerhead(s) and the end switch relays
illuminating the red LED light.
4 Zone
120/60/1vac 1.5A
24 VAC class 2
40 VA
5 Amp Max
1/6 hp, 5A
@ 120 VAC
24 VAC, 1A
8 per control
UL Approval
6 Zone
120/60/1vac 3A
24 VAC class 2
2 x 40 VA
2 x 5 amp fuses
1/6 hp, 5A
@ 120 VAC
24 VAC, 1A
16 per control
UL Approval
Stock Code Description Width Height Depth
18060 4 Zone with priority 10.75" 7" 2.75"
18062 6 Zone with priority 12.25" 8" 3"
Viega Zone Control
Wiring Thermostats
1. Connect the "R" terminal of the thermostat to the "R"
terminal of the Zone Control. "R" supplies power to
the thermostat.
2. Connect the "W" terminal of the thermostat to the
"W" terminal of the Zone Control. "W" is the switching
signal.
3. Connect the "C" terminal of the thermostat to the "C"
terminal of the Zone Control. "C" is common.
Wiring Powerheads
1. Connect the black wire of the powerhead to the "1"
terminal of the Zone Control.
2. Connect the white wire of the powerhead to the "2"
terminal of the Zone Control.
3. Connect a jumper from the "3" terminal to "4" terminal
of the Zone Control.
NOTE: Factory jumper between 3 and 4 must remain in
place for use with 2-wire Powerhead. Factory jumper
between 3 and 4 must be removed for use with
4-wire Powerhead.
Priority Operation
Switching the DIP switch to Priority "ON" will cause
all other zones to stop operation until the prioritized
zone is satised. When Priority is "OFF" all zones
work independently.
Warning
Wiring connections must be made in accordance with all applicable electrical codes. Use copper wire only with
a minimum temperature rating of 75°C. Failure to follow this instruction can result in personal injury or death
and / or property damage. 12 - 18 gauge wire recommended for 120 VAC connections, 14 - 22 gauge wire for
24 VAC connections.