Install Instructions

Viega IM-MTL 0612
724607
23
9. With V2 ACTUATOR inserted into
the tool, open the V2 ACTUATOR as
shown and connect V2 ACTUATOR
to the XL-C Ring.
10. Place V2 ACTUATOR onto XL-C
Ring and start pressing process.
Hold the trigger until the Actuator
has engaged the XL-C Ring. Keep
extremities and foreign objects away
from XL-C Ring and V2 ACTUATOR
during pressing operation to prevent
injury or incomplete press.
11. Release V2 ACTUATOR from XL-C
Ring and then remove the XL-C
Ring from the fitting on completion
of press. Remove tag from fitting,
indicating press has been performed.