Product Overview
5 of 11
Viega... The global leader in plumbing, heating and pipe joining systems
301 N. Main, 9th Floor • Wichita, KS 67202 • Ph: 800-976-9819 • Fax: 316-425-7618 • www.viega.com
©2011, ProPress
®
, FostaPEX
®
, Seapress
®
, MegaPress
®
, MegaPressG
®
and Viega
®
are registered trademarks of Viega GmbH & Co. PureFlow
®
, Smart Connect
®
, Climate Panel
®
, Climate Mat
®
, Climate Trak
®
,
MANABLOC
®
, Radiant Wizard
®
, S-no-Ice
®
, Snap Panel
®
, XL
®
and XL-C
®
are registered trademarks of Viega LLC. MiniBloc
™
, ProRadiant
™
, PolyAlloy
™
, SmartLoop
™
and Zero Lead
™
are trademarks of Viega LLC;
GeoFusion
™
, ProPressG
™
and ViegaPEX
™
are trademarks of Viega GmbH & Co. KG.
Product
Instructions
PI-PR-561051 0312 (Enhanced Mixing Station)
Technical Data
167 °F (75 °C) 0.75 psi (0.05 bar)
194 °F (90 °C) 4.06 psi (0.28 bar)
230 °F (110 °C) 15.7 psi (1.08 bar)
Liquid temperature Min. inlet pressure
Supply voltage: 1x115V +/-10 %, 60Hz.
Motor protection: The pump requires no external
motor protection.
Enclosure class: Indoor use only, IP42.
CSA Enclosure Type 2.
Insulation class: F.
Relative air humidity: Maximum 95 %.
Maximum discharge pressure: 150 psi (10.34 bar).
Inlet pressure:
Sound pressure level: 43 dB (A).
To avoid condensation in the control box and stator,
the liquid temperature must always be higher than the
ambient temperature.
+32 °F
(0 °C)
+50 °F
(+10 °C)
+68 °F
(+20 °C)
+86 °F
(+30 °C)
+95 °F
(+35 °C)
+104 °F
(+40 °C)
Liquid temperature
Ambient
temperature
[°F (°C) ] Min. [°F (°C) ] Max. [°F (°C) ]
+36 °F
(+2 °C)
+50 °F
(+10 °C)
+68 °F
(+20 °C)
+86 °F
(+30 °C)
+95 °F
(+35 °C)
+104 °F
(+40 °C)
+230 °F
(+110 °C)
+230 °F
(+110 °C)
+230 °F
(+110 °C)
+230 °F
(+110 °C)
+194 °F
(+90 °C)
+158 °F
(+70 °C)
Maximum glycol concentrations:
50 % glycol @ 36 °F (2 °C).
Hydraulic performance change can be expected.
Watt readings: Accuracy +/-1 Watt.
Flow indicator:
Provides a relative indication of ow — should
not be used in lieu of a ow meter.
Check valve:
Use of check valve may reduce pump hydraulic
performance (up to -10%). Use check valve in
parallel pumping applications.
Curve conditions:
Test liquid: Airless water.
Curves apply to a density of 983.2 kg/m3 and a
liquid temperature of +140 °F (+60 °C).
All curves show average values and should not be
used as guarantee curves. If a specic minimum
performance is required, individual measurements
must be made.
Curves apply to a kinematic viscosity of 0.474 cSt.
Approximate power usage:
High xed speed 39W 45W
Medium xed speed 15W 30W
Low xed speed 5W 8W
Constant pressure 8W 45W
Constant pressure 14W 45W
Constant pressure 22W 45W
AutoADAPT 5W 45W
Speed Setting Min. Max.
III
II
I
III
II
I
III
II
I
III
II
I
III
II
I
III
II
I
III
II
I