11 Safety
11.1 Safety standards and Compliance
This product was tested to the following standards and found compliance.
11.1.1 Standards
Approval standards for the VIDRE LCD monitors are
FCC: CFR47, Part 15 / CISPR 22 3
rd
edition 1997 class A
ANSI C63.4 2003
Canadian ICES-003
CE: EN 55022 1998+A1, 2000+A2, 2003 Class A
EN 55024 1998+A1, 2001+A2, 2003
IEC: 61000-4 series
UL: UL 60950-1 2003 first edition
CSA: C22.2 No. 60950-1-03 1
st
edition 2003
TÜV: EN 60950-1/A11 2004
11.1.2 Insulation Resistance
The resistance of the insulation between the power terminal and the earth ground contact is
more than 10 MÙ while withstanding a voltage of 500 V DC.
The power terminal and the earth ground contact is more than 4 MÙ while withstanding a
voltage of 500 V DC.
11.1.3 Insulation Dielectric Strength
The evaluation conforms to safety standard of shipment area.
There is no breakdown of the insulators or short circuits when applying an alternating potential
of 1.5 kV AC and 1.6 kV AC for a duration of 20 m and 3 seconds respectively between the
metallic chassis and the input power supply active and neutral terminals connected together.
11.1.4 Environment
The unit is tested to operate in an environment with temperatures of 0°C up to +50°C at a
humidity range of 20 - 80 % in a altitude not more than 3.000 m.
Storage characteristics are -20°C up to +60°C at 20 - 85% humidity in a altitude not more
than 3.000 m.