Troubleshooting guide
PAGE 14 of 36  VR GSM DOOR INTERCOM TECHNICAL MANUAL    VER2.0.0 
PUSH TO EXIT BUTTON AND AUXILIARY INPUTS/OUTPUTS 
PUSH TO EXIT BUTTON, TRIGGERS 
RELAY FOR PROGRAMMED TIME 
AUXILIARY OUTPUT (OPEN COLLECTOR), 
TRIGGERS WHEN C1 & AI ARE SHORTED 
AUXILIARY INPUT, TRIGGERS 
AUXILIARY OUTPUT (AO) 
AUXILIARY INPUT, SENDS A SMS MESSAGE 
TO THE TELEPHONE NUMBER STORED IN 
MEMORY LOCATION 020 
(NOTE: Once triggered, it can’t be triggered again for 4 
minutes. This avoids multiple SMS messages being sent 
for the same alarm) 