Specifications
Specifications
VTM-2000 Installation and Operation Handbook
A-3
Control
GPI
Four total for input select A, B, C, and D.
GPO
One summary alarm
Connector
15-pin HD (high density) D-sub, female
Input Impedance
10 kΩ returned to +5 VDC
Alarm Output
Relay closure
Maximum relay current
350 mA @ 30 VDC
Remote
One RJ-11 female for use with the RCU-2000
Display
General
A quadrant display for viewing an input on up to four different displays
as picture, waveform, vector, audio, and alarm status simultaneously or
individually as a full screen display of each separately
Waveform
Composite. YC
B
C
R
RGB, or YRGB parade/overlay of like formats
Sweep time base
1H or 2H with x1, x5, and x10 horizontal magnification
1V or 2V with x1, x2.5, x5, and x25 horizontal magnification
Waveform accuracy
≤ 1%
Vector
R-Y vs. B-Y for Analog C
B
vs. C
R
for SD
Vector Accuracy
≤ 1°
Audio (Optional)
2 or 4 channels displayed simultaneously