Specifications

Global Setup Menu Functions
VTM-2000 Installation and Operation Handbook
4-7
Table 4-6. Audio Alarms Menu (continued)
ENABLE CH 1 -
ENABLE CH 2 -
ENABLE CH 3 -
ENABLE CH 4 -
ANALOG LEVEL
-50 TO 0 dBu (-50 dBu is
Default)
ANALOG
DURATION
0 TO 60 SECONDS (2
Seconds is Default)
ENABLE CH 1 -
ENABLE CH 2 -
ENABLE CH 3 -
ENABLE CH 4 -
DIGITAL LEVEL
-60 TO 0 dBFS (-60 dBFS
is Default)
LOSS OF SOUND
DIGITAL
DURATION
0 TO 60 SECONDS (2
Seconds is Default)
Table 4-7. Video Alarms, Digital Menu
OFF (Default) -
ENABLE
ON -
LOSS OF CARRIER
DURATION
0 TO 60 Seconds (2
Seconds is Default)
-
OFF (Default)
ENABLE
ON
THRESHOLD
650 TO 750 mV (710 mV
is Default)
SENSITIVITY
1 TO 20 CES (15 CES is
Default)
RGB GAMUT
UPPER
DURATION
0 TO 60 Seconds (2
Seconds is Default)
OFF (Default)
ENABLE
ON
THRESHOLD
-50 TO 50 mV (-10 mV is
Default)
SENSITIVITY
1 TO 20 CES (15 CES is
Default)
DIGITAL GAMUT
RGB GAMUT
LOWER
DURATION
0 TO 60 SECONDS (2
Seconds is Default)
OFF (Default) -
ENABLE
ON -
EDH
DURATION
0 TO 60 Seconds (2
Seconds is Default)
-