Specifications

General Operation
VTM Series Installation and Operation Handbook
3-60
Figure 3-44. Eight Bar Graph Display Diagram
Table 3-35. Description of Eight Bar Graph Display Diagram
Field
Identifier
Field information
Nomenclature
1
Input Displays the user-configurable source IDs for the input and
routers.
2
Audio Type Displayed as Analog, AES, Embedded, Dolby AES, Dolby
Embedded.
3
Audio Input The displayed information is option dependent. Shown as 1
to 16 (analog is 1 to 8, AES is 1 to 16 or 1 to 8, and
Embedded is 1 to 16).
4
Meter Response Displays the selected meter response: VU, Peak, True Peak,
VU + Peak, VU + True Peak, Loudness, Custom
5
Scale Selection Displays the selected meter scale: Type I, Type IIa, Type IIb,
Type I + 8, Nordic, DIN 45406, dBFS, Zero REF dBFs.
6
Phase Bar (1) Phase Meter of bar graph 1
7
Phase Bar (2) Phase Meter of bar graph 2
8
Phase Bar (3) Phase Meter of bar graph 3
9
Phase Bar (4) Phase Meter of bar graph 4
10
Audio Graticule (with
meter labels)
Shown as L1, R1, L2, R2, L3, and R3 (or Custom label).
11
Zoom
Zoom (when enabled)
Blank when disabled
Press the ZOOM button to cycle through the Zoom
modes
12
Level Meters Shows the peak and reference levels for the signal. This can
be adjusted in the AUDIO SETUP\METER SETUP\REF
DIGITAL (or ANALOG) menu.