Specifications
General Operation
VTM Series Installation and Operation Handbook
3-36
Table 3-16. Vector Analog Pane Menu Structure
75%
ANALOG STANDARD
100%
POSITION
USE H POS AND V POS KNOB. PRESS KNOB FOR
CENTER.
SETUP
Press ENT
Table 3-17. Vector SD-SDI Pane Menu Structure
75%
SD STANDARD
100%
OFF
SCALE SD TO
COMPOSITE
ON
POSITION
USE H POS AND V POS KNOB. PRESS KNOB FOR
CENTER.
SETUP
Press ENT
Table 3-18. Vector HD-SDI Pane Menu Structure
75%
100%
HD STANDARD
75% + 100%
OFF
SCALE HD TO
COMPOSITE
ON
POSITION
USE H POS AND V POS KNOB. PRESS KNOB FOR
CENTER.
VECTOR SETUP
Press ENT
Standard
NOTE: This selection also is reflected in the Gamut display for the selected pane.
Standard is used to set the marks on the vector display. The marks on the vector help
to visualize the minimum/maximum value of a video signal. The position of the
excursion marks are 75% or 100% for analog, SD, and HD. Also, the HD standard can
be selected as 75% and 100% simultaneously.
Scaled to Composite (SD and HD only)
Also, with an HD or SD signal, the Scaled to Composite menu can be used to scale the
SD or HD vector to reflect a composite format.
Vector Position (Centering the Vector)
Centering the vector should be a one-time calibration and can be done in composite
format. Centering of the vector can be accomplished by adjusting the Vector V
position and Vector H position in the VECTOR PANE menu.