Specifications
Global Setup Menu Functions
VTM Series Installation and Operation Handbook
4-23
Table 4-11. TS Alarms Menu (VTM-OPT ASI) (continued)
MGT -
VCT -
RRT -
ETT -
CRC ERROR (ATSC)
(CONT)
DURATON
0 TO 60 SECONDS (2
Seconds is Default)
PAT -
CAT -
PMT -
SDT -
NIT -
BAT -
TOT -
EIT -
CRC ERROR (DVB)
DURATON
0 TO 60 SECONDS (2
Seconds is Default)
ENABLE -
DISCONTINUITY
10 to 1000 ms (100 ms is
Default)
PCR ERROR
REPETITION
10 ms to 1000 ms (40 ms
is Default)
ENABLE -
PCR ACCURACY
THRESHOLD
100 ns TO 2000 ns (500
ns is Default)
ENABLE -
PTS ERROR
THRESHOLD
100 ns TO 2000 ns (500
ns is Default)
ENABLE -
ETR 290 2
nd
PRIORITY (CONT)
CAT ERROR
DURATON
0 TO 60 SECONDS (2
Seconds is Default)
ENABLE -
SHORT RANGE
10 to 100 ms (25 ms is
Default)
NIT ACUTAL
ERROR (DVB only)
RANGE
1000 ms TO 50000 ms
(10000 ms is Default)
ENABLE -
ETR 290 3
rd
PRIORITY
NIT OTHER ERROR
(DVB only)
RANGE
1000 ms TO 50000 ms
(10000 ms is Default)
(Table continues on next page)