Specifications
Global Setup Menu Functions
VTM Series Installation and Operation Handbook
4-21
Table 4-10. Time Code Alarms Menu
ALARM
REPORTING SETUP
MATRIX SCREEN -
OFF (Default) -
ON -
LTC LOSS OF TIME
CODE
DURATION
0 TO 600 SECONDS
(240 Seconds is Default)
OFF (Default) -
ON -
RANGE
0.2 TO 1.8 VOLTS (0.5 is
Default)
LTC TIME CODE
LEVEL
DURATION
0 TO 600 SECONDS
(240 Seconds Default)
OFF (Default) -
ON -
RANGE
1.5 TO 10.5 LINES (10.5
is default)
LTC TIME CODE
FRAMING
DURATION
0 TO 600 SECONDS
(240 Seconds Default)
OFF (Default) -
LTC TIME CODE
CONTINUITY
ON -
OFF (Default) -
ON -
THRESHOLD
1 TO 30 FRAMES (1
Frame is Default)
LTC/DVITC
COMPARE (TC
SYNC)
DURATION
0 - 60 SECONDS (2
Seconds is Default)
OFF -
ON -
D-VITC LOSS OF
TIME CODE
DURATION
0 TO 600 SECONDS
(240 Seconds Default)
ENABLE -
LINE 525
525 LINE:
10 TO 20 LINES
(LINE 14 is Default)
LINE 625
625 LINE:
6 TO 22 LINES
(LINE 14 is Default)
D-VITC LINE
DURATION
0 TO 600 SECONDS
(240 Seconds Default)
D-VITC CONTINUITY
ENABLE -
ENABLE -
D-VITC CRC
DURATION
0 TO 600 SECONDS
(240 Seconds is Default)