Specifications

Global Setup Menu Functions
VTM Series Installation and Operation Handbook
4-12
Table 4-8. Video Alarms, Digital Menu (continued)
OFF - -
ON - -
CRC- HD
DURATION
0 TO 60 Seconds (2
Seconds is Default)
-
OFF - -
ON - -
LOSS OF CARRIER
DURATION
0 TO 60 Seconds (2
Seconds is Default)
-
OFF (Default) - -
ON - -
THRESHOLD
0 TO 350 mV (300 mV is
Default)
-
SENSITIVITY
2 TO 20 CES (2 CES is
Default)
-
LOSS OF ACTIVE
VIDEO – DIG
DURATION
0 TO 60 0 TO 60
Seconds (2 Seconds is
Default)
-
OFF (Default) - -
ON - -
LOSS OF
REFERENCE
DURATION
0 TO 60 Seconds (2
Seconds is Default)
-
ENABLE -
END OF TOP BORDER
525
NTSC LINES:
+21 TO +139
(21 is Default)
TOP BORDER
END OF TOP BORDER
625
PAL LINES:
+19 TO +159
(19 is Default)
ENABLE -
START OF BOTTOM
BORDER 525
NTSC LINES:
+140 TO +262
(140 is Default)
LETTERBOX - SD
BOTTOM BORDER
START OF BOTTOM
BORDER 625
PAL LINES:
+160 TO +312
(160 is Default)
(Table continues on next page)