Specifications

Specifications
VTM-200 Installation and Operation Handbook A-4
Outputs (continued)
AUDIO
Two analog stereo pairs (L1, R1; L2, R2), user selectable from among
the audio input pairs, are available at a push-on, mating connector (with
audio option installed).
AUDIO OUTPUT SIGNAL
LEVEL
+4 dBm (600Ω balanced) ± 1 dB for any situation where the input level
is equal to the selected reference level, except for the selection of the
dBfs scale. When the dBfs scale is selected, the analog output level is
-4 dBm ± 1 dB with a -20 dBfs input regardless of the selected
reference.
AUDIO METER DISPLAY
Bar graph displays of L1, R1, L2, R2 audio channels
AUDIO METER ACCURACY
Non-Zoomed Display
± 1 dB for readings down to -26 dB
± 3 dB for readings of -30 dB and below
Zoomed Display
± 0.5 dB
AUDIO PHASE DIFFERENCE
INDICATION
Differential phase displays for L1, R1 and L2, R2 are provided covering
the range of 0° to 180°
Interface
COM
A standard 9-pin, female, “D” connector is available at the back panel to
provide RS-232 serial data communication with an external computer.
RS-232/RS-422
COMMUNICATION
PARAMETERS
No parity, 8 data bits, 1 stop bit
Supported baud rates: 300, 1200, 2400, 4800, 9600, 19200, 38400
KEYBOARD
A standard 6-pin, mini DIN connector is provided at the back panel. A
computer keyboard up to 25 feet away from the VTM-200 may be used
for remote control.
GPI / TALLY
A standard 9-pin, male, “D” connector is available at the back
panel.
Momentary contact closures (> 0.5 seconds) may be used to select
one of the 4 input signals for display, and to provide ON AIR status.
(Input impedance is 10KΩ @ +5 VDC.) A contact closure (100 mA
max., 50 VDC max.) provides error status summary.
Power Requirements
AC POWER SOURCE
90-264 VAC, 50-60 Hz
POWER CONSUMPTION
150 VA