6.1.4.2 Pump and alarms connection
Connect the Pan & Tilt to the J9 terminal contacts as
described in the table below.
J9
A B
RS485
GND
AVL
A2L
A1L
GCW
CW
GCP
CP
L2
L1
Fig. 7
The AVL, GND, A1L 2 A2L contacts can only
be used in pump models equipped with
oats.
PUMP AND ALARMS CONNECTION
Connector Function ULISSE ULISSE
COMPACT
CP Pump control O1 R2A
CGP GND Pump
control
C1 R2B
AVL Float alarm AL1 W
GND GND Float
alarm
COM / AGND G
A1L Float alarm
(Clean con-
tact)
Alarm contact
1 (only for
network
version)
-
A2L Float alarm
(Clean con-
tact)
ALARMS
contact (only
for network
version)
-
Tab. 2
The pump can be switched on manually
(without using the pan & tilt) using the
CP and CGP dry contacts. This solution is
particularly suitable when washing the
housing windows.
6.1.4.3 Wiper connection
If you are using a pan & tilt equipped with
a wiper, skip the instructions here below
and follow those provided in the relative
manual.
For the manual activation of the wiper, refer to the J9
terminal contacts (Fig. 7, page5).
WIPER CONNECTION
Connector Function
CW Wiper control (clean contact)
CGW GND Wiper control (clean contact)
Tab. 3
Join connector J7 to the wiper observing the order of
the PERM, SW and COM contacts (refer to the wiper
manual).
J7
PERM
SW
COM
WIPER
Fig. 8
The voltage applied to connector J7
(WIPER) is the same as the one delivered
to the power supply terminal. Use a wiper
having electric characteristics that are
suitable for the power supply voltage.