10
6.1.5.2 Mounting with pan & tilt
The xing base of the housing must be positioned
laterally.
Fig. 9
6.1.5.3 Fixing the sunshield (optional)
Screw the equipped exagonal spacers on the anges
of the housing (01). Position the sunshield on the
housing (02) and x it on the spacers with the
equipped screws (03).
01
03
02
Fig. 10
7 Configuration
7.1 Serial control
For a full control of the product it is necessary to
install the FLIR Camera Controller GUI software and
use a USB/RS-422 converter with galvanic insulation
(e.s. ICP CON I-7561) or an equivalent one.
USB RS-422
USB/RS-422
converter
Fig. 11
7.2 Connection of the USB/RS-
422 converter
Connect the USB/RS-422 converter to the terminals of
the J2 connector of the housing board, as described
in the table (Tab. 2, page9).
It might be necessary to terminate the two data
lines as described in the chapter (6.1.4 Serial line
terminations, page9).