14.5 Electrical rating
ELECTRICAL RATING
Power Supply Normal usage to be specied on product label Short term de-icing cicle. Peak maintaining a mini-
mum internal temp at 5°C
230Vac 0.11A, 50/60Hz, 25.3W 0.52A, 50/60Hz, 120W
24Vac 1.08A, 50/60Hz, 25.9W 5A, 50/60Hz, 120W
120Vac 0.21A, 50/60Hz, 25.2W 1A, 50/60Hz, 120W
Tab. 12
14.6 Cable glands
SELECTION TABLE FOR CABLE GLANDS
Zone, Gas Cable gland
type
Certication Operating
temperature
Cable Cable glands
part code
Diameter of
the external
cable (mm)
Under armor
cable diame-
ter (mm)
IIC, Zone 1 or
Zone 2
IIB or IIA,
Zone 1
Barrier IECEX/ATEX/
GOST
-60 / +80°C
(-76°F /
+176°F)
Not armored OCTEXB3/4C 13 - 20.2
Armored OCTEXBA3/4C 16.9 - 26
IIB or IIA,
Zone 2
With gasket IECEX/ATEX/
GOST
-60 / +100°C
(-76°F /
+212°F)
Not armored OCTEX3/4C 13 - 20.2
Armored OCTEXA3/4C 16.9 - 26 11.1 - 19.7
ATEX -20 / +80°C
(-4°F / + 176°F)
Not armored OCTEX3/4 14 - 17
Armored OCTEXA3/4 18 - 23 14 - 17
Tab. 13