ELECTRICAL RATING
Power Supply Normal usage to be specied on product label Short term de-icing cicle. Peak maintaining a mini-
mum internal temp at 5°C
230Vac 0.11A, 50/60Hz, 25.3W 0.52A, 50/60Hz, 120W
24Vac 1.08A, 50/60Hz, 25.9W 5A, 50/60Hz, 120W
120Vac 0.21A, 50/60Hz, 25.2W 1A, 50/60Hz, 120W
Tab. 12
14.6 Cable glands
SELECTION TABLE FOR CABLE GLANDS
Zone, Gas Cable gland
type
Certication Operating
temperature
Cable Cable glands
part code
Diameter of
the external
cable (mm)
Under armor
cable diame-
ter (mm)
IIC, Zone 1 or
Zone 2
IIB or IIA,
Zone 1
Barrier IECEX/ATEX/
GOST
-60 / +80°C
(-76°F /
+176°F)
Not armored OCTEXB3/4C 13 - 20.2
Armored OCTEXBA3/4C 16.9 - 26
IIB or IIA,
Zone 2
With gasket IECEX/ATEX/
GOST
-60 / +100°C
(-76°F /
+212°F)
Not armored OCTEX3/4C 13 - 20.2
Armored OCTEXA3/4C 16.9 - 26 11.1 - 19.7
ATEX -20 / +80°C
(-4°F / + 176°F)
Not armored OCTEX3/4 14 - 17
Armored OCTEXA3/4 18 - 23 14 - 17
Tab. 13