SOLUTION Wait until the end of the pre-heating
procedure. If the air temperature is
too low the unit will remain disabled
and the following message will be
shown:
Address : 1
DE-ICE PROCEDURE
------------------------
SYSTEM BLOCKED
TEMPERATURE TOO LOW
------------------------
PROBLEM Error E1-AUTOPAN WITHOUT
LIMITS.
CAUSE The two presets used as limits
have not been programmed.
SOLUTION Program the two presets and then
update the Autopan conguration
menu (10.2 Saving the current
position (Preset), page65 and 9.6.4.7
Autopan Menu, page47).
PROBLEM
Error E2-WIPER BLOCKED.
CAUSE The wiper is either jammed or
broken.
SOLUTION Check that the wiper is free to
move; if the problem persists, seek
assistance.
PROBLEM Error E3-PATROL WITHOUT
PRESET or error E4-PATROL, 1
PRESET ONLY.
CAUSE The presets have not been
programmed.
SOLUTION Program two or more presets and
then update the Patrol conguration
menu (10.2 Saving the current
position (Preset), page65 and 9.6.4.6
Patrol Menu, page47).
PROBLEM
Error E5-IR TEMP. TOO HIGH or
error E6-IR FAULT.
CAUSE The infrared illuminator is not
working properly.
SOLUTION Seek assistance.
PROBLEM
Error E7-PRST. NOT
CONFIGURED.
CAUSE Recalling of a non programmed
preset.
SOLUTION Save the preset using the relative
control (10.2 Saving the current
position (Preset), page65).
PROBLEM
Error E8-TOUR NOT
CONFIGURED.
CAUSE Recalling of a non congured
Tour.
SOLUTION Save the Tour using the relative
control (10.6 Recalling a pattern
(Tour), page65).
PROBLEM
Error E9-TEMP. TOO LOW.
CAUSE The environment temperature is
too low.
SOLUTION The movements of the P&T unit
is blocked to prevent mechanical
damage.