SOLUTION Wait until the end of the pre-heating
procedure. If the air temperature is
too low the unit will remain disabled
and the following message will be
shown:
Address : 1
DE-ICE PROCEDURE
------------------------
SYSTEM BLOCKED
TEMPERATURE TOO LOW
------------------------
PROBLEM Error E1-AUTOPAN WITHOUT
LIMITS.
CAUSE The two presets used as limits
have not been programmed.
SOLUTION Program the two presets and then
update the Autopan conguration
menu (10.2 Saving the current
position (Preset), page65 and 9.6.4.7
Autopan Menu, page47).
PROBLEM
Error E2-WIPER BLOCKED.
CAUSE The wiper is either jammed or
broken.
SOLUTION Check that the wiper is free to
move; if the problem persists, seek
assistance.
PROBLEM Error E3-PATROL WITHOUT
PRESET or error E4-PATROL, 1
PRESET ONLY.
CAUSE The presets have not been
programmed.
SOLUTION Program two or more presets and
then update the Patrol conguration
menu (10.2 Saving the current
position (Preset), page65 and 9.6.4.6
Patrol Menu, page47).
PROBLEM
Error E5-IR TEMP. TOO HIGH or
error E6-IR FAULT.
CAUSE The infrared illuminator is not
working properly.
SOLUTION Seek assistance.
PROBLEM
Error E7-PRST. NOT
CONFIGURED.
CAUSE Recalling of a non programmed
preset.
SOLUTION Save the preset using the relative
control (10.2 Saving the current
position (Preset), page65).
PROBLEM
Error E8-TOUR NOT
CONFIGURED.
CAUSE Recalling of a non congured
Tour.
SOLUTION Save the Tour using the relative
control (10.6 Recalling a pattern
(Tour), page65).
PROBLEM
Error E9-TEMP. TOO LOW.
CAUSE The environment temperature is
too low.
SOLUTION The movements of the P&T unit
is blocked to prevent mechanical
damage.