6.1.14 Setting the baud rate
To set the baud rate operate on DIP 2.
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
0
A
O
N
1
2
3
4 5
6
7
8
U
2
U
1
U
3
D
I
P
3
D
I
P
5
D
I
P
4
1
2
3
4
DIP 2
Fig. 37
Dip-switches 4, 3 and 2 are used to set the
communication rate of the device according to the
table below.
SETTING THE BAUD RATE DIP 2
Description
SW 1
SW 2
SW 3
SW 4
SW 5-6-7-8
Conguration
Baud rate
selection
ON ON ON 38400 baud
OFF
ON ON 19200 baud
ON
OFF
ON 9600 baud
OFF OFF
ON 4800 baud
ON ON
OFF
2400 baud
OFF
ON
OFF
1200 baud
ON
OFF OFF
600 baud
OFF
OFF
OFF
300 baud
Congurations
display
ON Display ena-
bled
OFF
Display disa-
bled
Tab. 5
6.1.15 Serial communication lines
To set the serial communication lines operate on
DIP 2.
The product is designed with two RS485 serial
communication lines which can have various settings
according to the positions of dip-switches 5 and 6 on
the DIP selector.
SERIAL COMMUNICATION LINES DIP 2
Description
SW 1-2-3-4
SW 5
SW 6
SW 7-8
Conguration (see
related chapters)
Serial line ON ON Two-way RS485 TX/
RX line
OFF
ON Line RS485-1 reception,
line RS485-2 repetition
ON
OFF
Two-way RS422 line
OFF OFF
One-way RS485 line
Tab. 6