Instruction Manual

EN - English - Instructions manual
10
4.1.1 Version with thermal imaging
camera
The device can be provided with a thermal imaging
camera, which is installed inside a second housing,
whose window is made mainly of germanium which
guarantees the same strength and security properties
as those for standard glass (Fig. 3 MPXT.,
page10).
The thermal camera is an Uncooled Vanadium Oxide
microbolometer (VOx) with spectral band 7.5-13.5
m; it delivers a thermal video of 320x 256 (PAL) and
320x240 (NTSC), with an image frequency of 8.3fps or
25 fps (PAL) and 7.5 or 30fps (NTSC).
The high sensitivity NEdT 50mK at f/1.0 ensures an
optimal thermal imaging. It supports 2x or 4x digital
zoom.
A choice of lens sizes is oered between 35mm,
25mm and 9mm, depending on the detection
distance required.
Fig. 3 MPXT.
4.2 Product markings
02
01
03
05
06 07 08 09
10
11
04
Fig. 4
1. CE symbol
2. Manufacturers name and address
3. Model identication code
4. Ambient temperature of use referring to model
identication code
5. Serial number (the serial number are 12 numeric
characters, the second and the third digits
dene the last two numbers of the year of
manufacture)
6. Power supply voltage (V)
7. Absorption current (A)
8. Frequency (Hz)
9. Housing power consumption (W)
10. ATEX certication:
• ATEX certicate number
• Classication for zone type, protection method,
temperature class for which this product may be
used in compliance with the ATEX directive
11. IECEx certication:
• IECEx certicate number
• Classication for zone type, protection method
and temperature class for which this product
may be used in compliance with the IECEx
standard