Manual

VQ-Series Real Time Splitter User Manual 04/08/2004 17:25
Videoswitch 7 Vq601c.doc
3.3.1 Exit SETUP Mode
When you have finished configuration, press the ALT key and key again to quit. All settings will be
saved, including the screen mode being displayed when this is done. If no keys are pressed for 30 seconds,
SETUP mode will automatically be terminated.
4 Keyboard & Alarm Connector Pin-Outs
Pin Description
1 Alarm 2
2 Alarm 4
3 Do not connect
4 Do not connect
5 Ground
6 Alarm 1
7 Alarm 3
8 Do not connect
9 Do not connect
10 Connect to Pin 15 to terminate the RS485 input unless
the twisted pair is being daisy-chained to another
terminated device.
11 Relay Normally Open
12 Relay Common
13 Relay Normally Closed
14 Remote Keyboard Input (RS485+)
15 Remote Keyboard Input (RS485-)
For RS232 remote control:
Connect Pin 14 to Pin 5
Connect RS232 data (TXD) to Pin15
Connect RS232 ground to Pin 5
The cable required for control from a PC with a 9-way D-type on its RS232 (COM) port is as follows:
PC VQ-Series Splitter
=== ==============
3-----------------------------------15
|----------14
5------------------------|-----------5
The VQ-Series Splitter can be controlled using the PC “VDM-Remote”, available free of charge from
www.videoswitch.co.uk
.