User manual
User Manual ADPRO
®
XOa Client Software
98 21796_05_preliminary
Parameter
Description
Operational state
Disarmed: inputs are only monitored when the system is disarmed;
consequently alarms will only be transmitted when the system is
disarmed.
Armed: inputs are only monitored when the system is armed;
consequently alarms will only be transmitted when the system is
armed.
Armed/disarmed: inputs are always monitored; consequently alarms
will always be transmitted.
Alarm Behaviour
Suppress alarm in this mode: it is possible to suppress alarms in
one or both operational states. When you activate this option, the
alarms that have been assigned to this profile will no longer be
activated during the suppression. By doing this you will disable
event-based recordings, emailing, PTZ triggers, logging….
Caution!
Suppressing alarms is not recommended. Do not use
this option unless specifically asked to do so, for example
by Xtralis Support staff.
Primary transmission: send events to the CMS via the main
connection;
Backup transmission: send events to the CMS via the provided
backup connection. The backup connection will only be used if
transmission on the main connection has failed!
Repeat tx alarm: send reminders at regular times (each
15 minutes*) if the alarm is sustained.
End of alarm tx: send message to CMS when input returns to
normal state (negative alarm).
Parallel transmission 1: sends event/message via parallel
transmission 1.
Parallel transmission 2: sends event/message via parallel
transmission 2.
Email transmission: sends event/message via email.
* The following alarm messages will only be repeated once every 24 hours:
65 license expired
66 license out of sync
67 application stopped
511 general isolation
1. Click Save to apply the new settings.