User manual
ADPRO
®
XOa Client Software User Manual
21796_05_preliminary 37
2. Select the desired I/O card set in the list, and then click Configuration. The following screen appears:
3. For each input, select the correct configuration: NEOL, SEOL, or DEOL; with NO or NC contact.
For more information, see the FastTrace 2 Hardware Installation Manual.
4. Select the Failsafe operation check box for each output that operates in failsafe mode. Failsafe
operation means that the relay is activated during idle state, and drops when the output is driven. The
advantage is that failsafe outputs drop to ‘alarm state’ when the power supply is cut.
5. Select the Watchdog check box for each output that operates in Watchdog mode. Watchdog
operation means that the output is activated when the video system cannot reach the I/O card for
some time, as specified by Timeout (output activation). This situation can occur when the video
system hangs. Timeout values are specified in seconds.
6. If you use the watchdog feature, type the number of seconds after which the system must activate the
Watchdog output in the Timeout (output activation) box.
7. If you want the buzzer to sound during a watchdog alarm, check the Buzzer check box.
8. Click OK to save the settings.
Note
With an ENTRY system license you can install only 1 Main I/O card. Multiple Main I/O cards are
not supported. Also, an ENTRY system does not support Extension I/O cards. This is for
instance the case with the ADPRO RMG Lite.