3 Connections
3.1 Network and Modem (Ethernet/PPP)
You can connect the server to a local network or to a remote (PPP dial-in) network, applying an external
modem.
To set up the network connections, open System > Connections > Ethernet/PPP. Modify the settings and
click Save.
3.1.1 Ports
In this section you can set the ports that will be used.
Port
Description
Default value
Telnet port
The IP port used to make a Telnet connection.
23
Rtsp port
Real-time streaming protocol: the client uses this port to control the
video streaming.
You have to use the same value here as the value specified when
adding this video system in the XOa client!
(For more information, see Adding a Server to the XOa Client on
page 21.)
554
Control port
IP port used to exchange information between the server and the
XOa client software. (e.g. display status of inputs and outputs)
You have to use the same value here as the value specified when
adding this video system in the XOa client!
(For more information, see Adding a Server to the XOa Client on
page 21.)
2000
Video IC port
Port used to interconnect with S3100 security panels. This allows
starting a recording on an alarm detected on the security panel.
Use the same port as the one selected in the S3100 configurator!
10002
Network I/O port
Port used to poll the Net I/O modules. This port is fixed, you cannot
change it.
3041
Webserver port
Port used for the http protocol.
80
We strongly recommend using the default ports. If this is not possible, please document the use of the new
ports thoroughly.
If you change some settings, you may have to restart the server:
Click Yes to restart the video system and apply the new settings.