23.2 Isolating an Alarm Input
Isolating an alarm input means the alarm is no longer received. The isolated input is marked in brown in the
Status window.
When you isolate an input, the video system activates input I0511, and transmits the system message
0511 – [SYST] – GENERAL ISOLATION every 24 hours until you activate all isolated inputs again. The
Status button in the top menu changes shape: an orange coloured pin indicates that there are isolated
inputs.
One or more inputs are isolated; there are no other (not isolated) faults.
One or more inputs are isolated; there are other (not isolated) faults that you
need to check.
To isolate an alarm input, proceed as follows:
1. Click Status, and then click the tab that displays the input (General or I/O).
2. Right-click the desired input, and click Isolate.
The status bar colours brown.
3. To re-activate an isolated input, right-click the desired input again, and click Isolate.
23.3 Activating an Output Manually
To manually activate an output, right-click the desired output and click Activate.
Note
You cannot activate an output that is already active (= green colour). It is also not possible to
manually deactivate an active output.
23.4 General Status of the Video System
You can receive one of these messages when checking the status of your cameras, video system, and
inputs and outputs.
Cam x past analytics
Error during post motion analysis – contact your dealer.
Cam x sab analytics
Error in camera tampering analysis – contact your dealer.
Cam x recording
Camera images are currently being recorded to hard disk.
Cam x synch fault
No video signal on camera – check camera power supply or coax
cable.
Cam x Contrast fault
Camera lens covered or lighting suddenly switched off.
Cam x Sabotage fault
Camera displaced or lens fault or zoom/focus settings changed.