148 21796_05_preliminary
Click the Status button to see an overview with different status bars.
The General tab displays the information about the general RMG system, the interconnection, and the
cameras.
The I/O tab displays the information about on-the-box inputs and outputs (Main and Extension I/O), IP
camera inputs and outputs, workbit inputs and outputs, PIR inputs, and the analytic detail status inputs.
Place the mouse pointer on an indicator (status bar) to see a detailed description.
The bar colour indicates the status. The General pane (at the bottom of the screen) displays an overview of
the colours and a short explanation of their meaning:
Colour
Description
A light blue bar indicates that the item is in the normal state, or that it is configured.
For example, the bar CAMxx PERIMETER for a camera is blue if IntrusionTrace is active on
the camera, but no intrusion is detected at the moment.
A green bar indicates that the item is active and working without faults. For example, the bar
0510 – [SYST] – GENERAL RECORDING is green when the video system is recording.
A yellow bar indicates that there is a fault, and that you must take action. For example, the
bar CAMxx PERIMETER for a camera is yellow if IntrusionTrace is detecting an intrusion at
the moment.
A brown bar indicates that the input/fault is isolated.